An Alarming BAC(net) Pain - 2
Category: Jubilife
Description
Jubilife's security team looked into the BACnet traffic involving that IP address (10.120.50.12) and noticed that write-property commands were sent to that device. It is possible the heat detectors are being triggered by these write-property commands.
What is the BACnet object-name on the fire suppression device that was written to using the write-property commands?
Note: the object-name itself is never written to via write-property commands
Flag format: BACnet object-name. Example: HVAC-ABC**
Write-up
- To identify the device that was written to using the
write-propertycommands, we can filter the logs in theBACnetdashboard using the filterzeek.bacnet.pdu_service == write-property. - Upon applying the filter, we observe that the
write-propertycommands were sent to the device with IP address10.120.50.12andinstance number 14. - Once we have identified the device, we can proceed to examine the
read-property-acklogs of that particular device to find theobject-name. - We can further filter the logs using the following criteria:
destination.ip == 10.120.50.12,zeek.bacnet.pdu_service == read-property-ack,zeek.bacnet_property.property == object-name, andzeek.bacnet_property.instance_number == 14.
Flag: VENT-LB